EVK Helios
Dependencies
See the plugin dependencies for the Pleora eBUS plugin.
Configuration
System
By default the camera uses a static IP address: 192.168.x.x with subnet mask 255.255.255.0. The camera IP address can be found in eBUS Player, by connecting and viewing unreachable devices, this can for instance be 192.168.2.10. In this case the computer's interface should be set to static IP address in the range 192.168.2.0/24, for instance 192.168.2.1 with subnet mask 255.255.255.0.
perClass Mira
The EVK Helios EC64 has the following extra options available in the user interface:
- Spatial binning: possible values: 1x, 2x, 4x, 8x, defaults to 1x.
- Gain: possible values: Low, Mid, High, defaults to Low.
mira.ini
The EVK Helios has the following options available in the mira.ini file under the acq_EVKHelios section:
- flipSpatial: a boolean value to enable spatial frame flipping.
The EVK Helios EC64 has the following options available in the mira.ini file under the acq_EVKHelios section:
- binningEnabled: a boolean value to enable binning, defaults to true.
- binningSpectral: an integer value to define the amount of spectral binning, defaults to 1, possible values: 1, 2, 4, and 8.
- binningSpatial: an integer value to define the amount of spatial binning, defaults to 1, possible values: 1, 2, 4, and 8, also see Spatial binning.
- gain: an integer value to define the gain, defaults to 0, possible values: 0 (Low), 1 (Mid), 2 (High), also see Gain.
Troubleshooting
For issues with loading the plugin, see Plugin loading. For other issues with GigE based cameras, see GigE Vision.